APPLICATIONS:
This
architectural panel system allows the architect freedom of
choice in an aesthetically pleasing engineered exterior wall
system. Horizontally applied THERMAWALL 5000 panels use a
patented double seal integrated with a pressure equalized joint
following the Rain Screen Principle. The nominal 3/8” wide joint
provides a distinctive horizontal reveal between panels. The
optional folded (trimless) panel ends are sealed with a recessed
dry gasket at the vertical edges.
CONSTRUCTION:
THERMAWALL
5000 SERIES PANELS are insulated with a NON CFC thermo-setting
polyurethane insulation that meets model building code
specifications. Structural grade steel facings are precisely
roll formed and foam insulation is expanded between the metal
sheets in a state-of-the-art continuous line production sequence
that is fully computerized to ensure optimum quality and
consistency in every panel.
INSULATION:
THERMAWALL 5000 SERIES PANELS with foamed polyurethane
insulation are offered in a thickness range of 2" to 3",
providing insulation values of R-15 to R-23.
FACINGS:
THERMAWALL
5000 SERIES PANELS have standard 22/26 gauge facings of stucco
embossed galvanized steel to ASTM A-525 G-90 designation. Base
steel shall be structural quality to minimum Grade A 33,000 PSI,
conforming to ASTM A-446. Optional panel facings of galvalume,
aluminum or stainless steel are available on request in various
gauges.
COATING
SYSTEMS:
CBS
Coating Systems include “Kynar 500” PVF2 finishes with high
performance properties and a 20 year warranty, covering color
retention, chalk resistance and film integrity. Silicone
modified polyester (SMP), polyester and plastisol finish
coatings also offer outstanding performance and extended
warranties. Metallics and exotic color coatings are readily
available to the designer.
PERFORMANCE REQUIREMENTS:
FIRE:
Meets
special requirements of model building codes and is certified
and approved by the following authorities.
ULI - Underwriters Laboratories Inc.
FM - Factory Mutual
WH - Warnock Hersey
ULC - Underwriters Laboratories Canada
NYFC - New York State Toxicity Standard
FM-4880 - Passed testing for Class 1 Fire rating
ASTM-E84 - Flame Spread 17; smoke developed: 97
Finished Panel
ULC S102 - Flame Spread 22; smoke developed: 67
Finished Panel
ULC S101 - Passed Fire Endurance Tests without
fastening joint seams
UBC 17-6 - Passed Multi-story test with standard panels