APPLICATIONS:

This architectural panel system allows the architect freedom of choice in an aesthetically pleasing engineered exterior wall system. Vertically applied THERMAWALL 5500 panels use a patented double interlocking seal with a nominal 1/8” wide joint. These panels are installed as single piece units the full height of most buildings.

CONSTRUCTION:

THERMAWALL 5500 SERIES PANELS are insulated with a NON CFC thermo-setting polyurethane insulation that meets model building code specifications. Structural grade steel facings are precisely roll formed and foam insulation is expanded between the metal sheets in a state-of-the-art continuous line production sequence that is fully computerized to ensure optimum quality and consistency in every panel.

INSULATION:

THERMAWALL 5500 SERIES PANELS with foamed polyurethane insulation are offered in a thickness range of 2" to 3", providing insulation values of R-15 to R-23.

FACINGS:

THERMAWALL 5500 SERIES PANELS have standard 22/26 gauge facings of stucco embossed galvanized steel to ASTM A-525 G-90 designation. Base steel shall be structural quality to minimum Grade A 33,000 PSI, conforming to ASTM A-446. Optional panel facings of galvalume, aluminum or stainless steel are available on request in various gauges.

COATING SYSTEMS:

CBS Coating Systems include “Kynar 500” PVF2 finishes with high performance properties and a 20 year warranty, covering color retention, chalk resistance and film integrity. Silicone modified polyester (SMP), polyester and plastisol finish coatings also offer outstanding performance and extended warranties. Metallics and exotic color coatings are readily available to the designer.

PANEL DESIGN

The THERMAWALL 5500 SERIES PANEL utilizes a superior joint design providing concealed fastener anchorage affording connection of both metal skins to the building structure, double caulk seal provision and excellent air and water infiltration test results. Panels are available in a flat embossed exterior with choice of finish.

Panel coverage is available in 24", 30", 36" nominal widths.


PERFORMANCE REQUIREMENTS:

FIRE:

Meets special requirements of model building codes and is certified and approved by the following authorities.
ULI - Underwriters Laboratories Inc.
FM - Factory Mutual
WH - Warnock Hersey
ULC - Underwriters Laboratories Canada
NYFC - New York State Toxicity Standard
FM-4880 - Passed testing for Class 1 Fire rating
ASTM-E84 - Flame Spread 17; smoke developed: 97 Finished Panel
ULC S102 - Flame Spread 22; smoke developed: 67 Finished Panel
ULC S101 - Passed Fire Endurance Tests without fastening joint seams
UBC 17-6 - Passed Multi-story test with standard panels

THERMAL TRANSMISSION:

ASTM C-518
ASTM C-236

VAPOR BARRIER:

ASTM E283   Air inflation “O” at 20 PSI
ASTM E331   Water penetration “O” at 20 PSI

STRUCTURAL:

ASTM E72
Vacuum chamber tested for wind and suction load deflections on wall assemblies.

ASTM E72-9
The panel achieved a vertical load bearing capacity on standard width to maximum 19,800 lbs. compressive force at .06" deflection.

Fatigue Test:
Standard panels were tested by independent Laboratories for long term deflection failure. The panels exceeded 2 million alternate cycles without failure or damage.

BOND STRENGTH:

The panel was tested for Tensile Bond strength of the metal to foam interface to more than 1200 lb. force without delamination.

CBS
Home

bmil-logo-sm.gif (2810 bytes)
Capabilities

BMIL
Contact Us

61 Broadway Suite 1900 - New York, NY 10006-2701
Tel: 212-898-9699 - Fax: 212-514-9234