Econo Max Manufacturing, Inc
TempSentry Specifications

tempsentrysp.GIF (33469 bytes)

Power supply: 6 VDC - Solar or battery (batteries included).
Range: -40° to -120°F or -30° to +50°C
Accuracy: +/- 1.5 degrees between -20° to 110°F
+/- degree between -30° to30°C
Audio alarm: 80 to 90 dB pulsed
Visual alarm: Bright red @ 500 mcd pulsed
Relay: Normally open contacts, 24V maximum @ 0.5 amp.
Contacts close when alarm activates.
Contacts open when temperature returns to set points or if SILENCE key is pushed.
Batteries: (4) "AA" Alkaline. Average battery life: 2 to 5 years depending on use and available light.
Light requirements: 8-10 hours of normal indoor light daily. High light exposure to solar cells greatly extends battery life.
Fluorescent (200 LUX)
Incandescent (40 LUX)
Sensor: Wire length is 36" (914mm), sensor is 5/16" (7.94mm) in diameter. Plastic coated metal tip. Wire can be extended up to 100 ft (30mts)
L x W x D 5.75" x 3.50" x 1.30" (146 x 89 x 33mm)

Note: This unit in not for medical use.